Sizing a demister pad with Souders–Brown
A mist eliminator is a simple object with an unforgiving specification. Size it above its capacity and it floods; below, and it is money spent on pressure drop.
7 min read · updated 30 October 2026
A knitted wire mesh demister pad removes entrained liquid droplets from a gas stream. Droplets impinge on the wire, coalesce, and drain back against the flow. It works until the gas is moving fast enough to tear the coalesced liquid off the wire again — at which point the pad re-entrains and carries over.
The equation
V_max = K × √((ρ_liquid − ρ_gas) / ρ_gas)
V_max in m/s; densities in kg/m³ at operating conditions, not standard conditions.
K is an empirical capacity factor. It is not a universal constant — it varies with orientation, pressure, and how dirty the service is. Published values cluster around 0.107 m/s for the standard case.
K factors
| Condition | K (m/s) | Why |
|---|---|---|
| Horizontal pad, vertical flow | 0.107 | The standard reference case |
| Vertical pad, horizontal flow | 0.082 | Less effective capture area; drainage works against flow |
| Vacuum, below ~0.3 bara | 0.061 | Low gas density makes re-entrainment easier |
| High pressure, above ~20 bar | 0.082 | Denser gas carries more momentum |
| Fouling service | 0.076 | Allows for partial blinding in operation |
| Marine / floating installation | 0.090 | Vessel motion disturbs drainage |
Choosing the pad itself
Once velocity is settled, three parameters remain: thickness, density and wire diameter. They trade efficiency against pressure drop and fouling resistance.
| Target droplet | Wire Ø | Density | Thickness |
|---|---|---|---|
| ≥ 3 µm | 0.15 mm | 192 kg/m³ | 200 mm |
| ≥ 5 µm | 0.23 mm | 144 kg/m³ | 150 mm |
| ≥ 10 µm | 0.28 mm | 112 kg/m³ | 150 mm |
| Coarse / fouling | 0.28 mm | 80 kg/m³ | 100–150 mm |
Material
- SS 304 — clean hydrocarbon and steam service at moderate temperature.
- SS 316L — anywhere chlorides or amines are present, which covers most refinery and coastal duty.
- Monel 400 — seawater and hydrofluoric acid, where 316L pits.
- Copper — specific chemical duties and some cryogenic service.
- Polypropylene — low temperature, aggressive aqueous streams.
A worked example
- Liquid density
- 700 kg/m³
- Gas density
- 20 kg/m³ at operating pressure
- K factor
- 0.107 (horizontal pad, vertical flow, clean)
- V_max
- 0.107 × √(680/20) = 0.62 m/s
- Design velocity at 80%
- 0.50 m/s
- Pad area
- π × 1.8² / 4 = 2.54 m²
- Selection
- 150 mm, 144 kg/m³, 0.23 mm SS 304
- Segments through a 500 mm manhole
- 4
Segmentation
A pad has to pass through the manhole. Above roughly 1200 mm diameter it ships in overlapping segments, and the count follows from the manhole size rather than the vessel. Give us the manhole diameter with the enquiry and the segmentation is designed in rather than improvised on site.
When a pad is the wrong answer
- Heavily fouling or waxing service, where any mesh will blind — use a vane pack.
- Very high velocity duty that cannot be resolved by vessel diameter — use a cyclonic or vane separator.
- Sub-micron aerosols, which mesh will not capture — use a coalescing filter element.
You do not have to do this by hand — we built the calculator that runs these numbers.
Run the sizingCommon questions
- Should I use densities at standard or operating conditions?
- Operating conditions, always. Gas density changes dramatically with pressure, and it sits in the denominator of the equation — using a standard-condition figure can be wrong by an order of magnitude.
- What pressure drop should I expect?
- A clean 150 mm pad at design velocity typically runs around 2 mbar, rising as it fouls. Treat any calculated figure, including ours, as indicative — pressure drop depends on construction detail that only a vendor curve captures properly.
- How do I know if an existing pad is undersized?
- Carryover is the symptom. Calculate the actual velocity from current throughput and vessel area, compare it with V_max for your conditions, and if you are above about 85% the pad is the likely cause.